            上海恒遠生物科技有限公司>技術文章>人白介素2(IL-2)試劑盒說明書

            技術文章

            人白介素2(IL-2)試劑盒說明書

            閱讀:3674          發布時間:2011-9-9

            RD

             
            Human Interleukin 2 (IL-2)

            FOR RESEARCH USE ONLY

            Assay range30 pg/ml -1200 pg/ml                   96 determinations

            Purpose

            This kit allows for the determination of IL-2 concentrations in Human serum, cell culture supernates and other biological fluids

             

            Principle of the assay

            The kit assay Human Interleukin 2 (IL-2) level in the sampleuse Purified Human Interleukin 2 (IL-2)antibody to coat microtiter plate wells, make solid-phase antibody, then add Interleukin 2(IL-2) to wells, Combined antibody which With HRP labeled goat anti- Human become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of  Human Interleukin 2 (IL-2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

            Materials provided with the kit

            1

            wash  solution

            20ml×1bottle

            7

            Stopp Solution

            6ml×1 bottle

            2

            HRP-Conjugate reagent

            6ml×1 bottle

            8

            Standard2400pg/ml

            0.5ml×1 bottle

            3

            Microelisa stripplate

            12well×8strips

            9

            Standard diluent

            1.5ml×1bottle

            4

            Sample diluent

            6ml×1 bottle

            10

            Instruction

            1

            5

            Chromogen Solution A

            6ml×1 bottle

            11

            Closure plate membrane

            2

            6

            Chromogen Solution B

            6ml×1 bottle

            12

            Sealed bags

            1

            Specimen requirements

            1.       extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 to preserve, Avoid repeated freeze-thaw cycles.

            2.       Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

            Assay procedure

            1.       Dilute and add sample:Dilute Original density Standard as follow table:

            1200 pg/ml

            5 Standard

            150μl Original density Standard+150μl Standard diluent

            600 pg/ml

            4 Standard

            150μl 5 Standard+150μl Standard diluent

            300 pg/ml

            3 Standard

            150μl 4 Standard+150μl Standard diluent

            150 pg/ml

            2 Standard

            150μl 3 Standard +150μl Standard diluent

            75 pg/ml

            1 Standard

            150μl 2 Standard +150μl Standard diluent

            2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

            3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.

            4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.

            5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

            6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well.

            7.incubateOperation with 3.

            8.washingOperation with 5.

            9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37

            10.Stop the reactionAdd Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).

            11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

            Steps description

            Standard, Sample diluent

             

            Add Standard, Sample diluent, incubate for 30 min at 37.

             

            Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

             

            Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37.

             

            Add Stopp Solution

             

            Read absorbance at 450nm within 15 min

             

            calculate

            Calculate

            Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.

            Important notes

            1.       The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

            2.       washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

            3.       add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

            4.       if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

            5.       Closure plate membrane only limits the disposable use, to avoid cross-contamination.

            6.       The substrate evade the light preservation.

            7.       Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

            8.       All samples, washing buffer and each kind of reject should according to infective material process.

            9.       Do not mix reagents with those from other lots.

             

            Storage and validity

            1Storage  2-8.

            2validity six months.

             

            收藏該商鋪

            登錄 后再收藏

            提示

            您的留言已提交成功!我們將在第一時間回復您~

            對比框

            產品對比 產品對比 聯系電話 二維碼 意見反饋 在線交流

            掃一掃訪問手機商鋪
            18221656311
            在線留言
            主站蜘蛛池模板: 免费av深夜在线观看| 久久亚洲精品情侣| 国产黑色丝袜在线播放| 一区二区亚洲人妻精品| 中文字幕亚洲人妻一区| 福利视频一区二区在线| 精品少妇av蜜臀av| 一区二区亚洲人妻精品| 亚洲中文精品一区二区| 丁香五月亚洲综合在线国内自拍 | 免费午夜无码片在线观看影院| 国产精品国三级国产av| 国产午夜精品福利视频| 国产999久久高清免费观看| 国产资源精品中文字幕| 亚洲欧洲日韩精品在线| 亚洲成A人片在线观看的电影| 少妇上班人妻精品偷人| 国产不卡一区不卡二区| 欧洲精品色在线观看| 国产精品人妻中文字幕| 亚洲人妻精品一区二区| 亚洲av日韩在线资源| 日本精品不卡一二三区| 中国熟女仑乱hd| 国产精品免费视频不卡| 巨爆乳中文字幕爆乳区| 美女自卫慰黄网站| 欧美福利电影A在线播放| 福利视频在线一区二区| 亚洲国内精品一区二区| 日韩精品区一区二区三vr| 国产在线播放专区av| 亚洲天堂av日韩精品| 国产一区二区在线有码| www久久只有这里有精品| 国内精品无码一区二区三区 | 国产av一区二区不卡| 国产一区二区日韩在线| 亚洲人成色99999在线观看| 久久精品国产蜜臀av|