            首頁   >>   技術(shù)文章   >>   不同接觸角儀軟件Young-Laplace方程擬合接觸角對比

            美國科諾工業(yè)有限公司 (...

            立即詢價

            您提交后,專屬客服將第一時間為您服務(wù)

            不同接觸角儀軟件Young-Laplace方程擬合接觸角對比

            閱讀:8030      發(fā)布時間:2015-5-29
            分享:

            本視頻中演示了采用Young-Laplace方程擬合時各家接觸角儀公司軟件的區(qū)別。從測試結(jié)果來看,接觸角變化范圍從103-105度之間,屬于一個合理的變化范圍。這種變化由各種因素造成,如水的揮發(fā)等。

             

             

            另可參考如下資料,我們發(fā)現(xiàn)國外的部分生產(chǎn)廠的接觸角儀軟件使用Young-Laplace擬合時,90-140度時,測值偏大5度,而大于140度時,測值偏大約10度。

            We measured contact angle of same sample with 4 different software from Kruss, Dataphysics, Biolin and KINO. And we measured contact angle of sample by Biolin's sofware - OneAttension V2.4 at first because only this software cannot import images into software and calculate contact angle for imported image. Other sofwares such as DSA1.92 and DSA3.0 from Kruss, and SCA202 from Dataphysics and CAST3.0 from KINO can all import image into software and can calculate contact angle using different method such as circle fitting method, ellispe fitting method and Young-Laplace equation fitting method.

            At this article, we just show you the calculated result by different company's software. Comparison of measured result maybe has some existed deviation due to our misoperation. You can contact us to obtain the recorded video for measuring process of contact angle.

            And from the comparison of measured contact angle from different drop shape software, may safely draw a conclusion that:

            1, When contact angle below 3°:  anti-dazzling screen must be used to get sharp drop shape and when using Young-Laplace equation fitting method, only sofware from Biolin (OneAttension V2.4) is failure to fitting the drop shape and get a acceptable contact angle.

            2, When there exists some noise points or poor backgroud, tangent method based on parts of drop profile will  failure to fitting the drop shape and get a acceptable contact angle.

            3, When contact angle between 90°-140°, calculated contact angle based on Young-Laplace equation fitting method from drop shape analysis software from Kruss, Dataphysics and Biolin will be larger than other mehod such as circle fitting and ellispe fitting about 3-5° when circle fitting or ellispe fitting can fitting the drop shape. And also this value based on Young-Laplace equation fitting method is larger than ADSA-RealDrop based method from KINO about 3-5°.

            4, When contact angle larger than 140°,  calculated contact angle based on Young-Laplace equation fitting method from drop shape analysis software from Kruss, Dataphysics and Biolin will be larger than other mehod such as circle fitting and ellispe fitting about 8-10° when circle fitting or ellispe fitting can fitting the drop shape. And also this value based on Young-Laplace equation fitting method is larger than ADSA-RealDrop based method from KINO about 8-10°.

            5, Calculated ontact angles by different method from KINO's sofware CAST3.0 are almost kept same when both of them fitting drop shape correctly.

             Please be noted that,

            1, A basic principle is contact angle is calculated from tangent at contact point or curve radius at contact point. And when fitting drop profile with some equation of curve, if result of fitting is good, calculated contact angle will be almost same. In other words, Young-Laplace equation can be used to calculate contact angle when drop shape cannot fitting with circle equation due to effect of gravity. But if we used other equation of curve and fitting it correctly, the result will be kept almost same.

            2, Red number means it is failure to fitting drop profile with current method. And "—" means current method cannot calculate any result automatically.  

            Comparison of calculated contact angle based on different method and different company such as Kruss, Dataphysics, Biolin and KINO.

            會員登錄

            請輸入賬號

            請輸入密碼

            =

            請輸驗證碼

            收藏該商鋪

            標簽:
            保存成功

            (空格分隔,最多3個,單個標簽最多10個字符)

            常用:

            提示

            您的留言已提交成功!我們將在第一時間回復(fù)您~
            在線留言
            主站蜘蛛池模板: 亚洲国产成人资源在线| 野外做受三级视频| 日本熟妇XXXX潮喷视频| 中文字幕无线码免费人妻| 高清无码爆乳潮喷在线观看| 人妻少妇偷人作爱av| 国产AV影片麻豆精品传媒| 四虎永久精品免费视频| 男人狂桶女人出白浆免费视频| 亚洲中文字幕日产无码成人片 | 久久精品国产福利一区二区| 亚洲国产精品一区二区第一页| 视频一区视频二区制服丝袜| 精品国产免费一区二区三区香蕉| 国产成人午夜福利精品| 亚洲欧美日韩成人综合一区| 精品视频不卡免费观看| 人妻中文字幕精品一页| 精品国产成人午夜福利| 亚洲国产精品久久久天堂麻豆宅男| 四虎影视一区二区精品| 亚洲中文字幕在线二页| 精品国产中文字幕懂色| 亚洲精品漫画一二三区| 亚洲一区二区精品动漫| 亚洲欧美人成网站在线观看看| 一本一道av无码中文字幕麻豆 | 国产精品自拍午夜福利| 亚洲第一极品精品无码久久| 丰满少妇内射一区| 国产精品欧美福利久久| 中文字幕亚洲国产精品| 欧美老少配性行为| 四虎在线播放亚洲成人| 少妇被黑人到高潮喷出白浆| 偷拍专区一区二区三区| 欧美国产日产一区二区| 91福利视频一区二区| 2021国产成人精品久久| 午夜在线观看成人av| 久久午夜无码免费|